Physio-Control LIFEPAK CR2 AED
The LIFEPAK CR2 AED response system empowers bystanders to help save lives. Innovative, easy to operate technology allows continuous CPR and help streamline communication across the systems of care.
The LIFEPAK CR2 defibrillator connects all teams involved in the response – reducing delays in treatment and supporting improved care across the lifesaving system. Advanced technology including cprINSIGHT analysis technology, Wi-Fi connectivity and continuous self-monitoring enables AEDs and rescuers to be prepared to deliver swift, lifesaving treatment.
- Continuous CPR improves blood circulation and increases chances of survival. The LIFEPAK CR2 is the only AED currently available that allows chest compressions during electrocardiogram (ECG) rhythm analysis, reducing pauses between CPR and defibrillation.
- Simple graphics, audible instructions and automated features help users remain focused during a sudden cardiac arrest emergency. Dual language capabilities and ClearVoice technology help users understand and hear voice prompts.
- Wi-Fi connectivity gives emergency responders a complete picture of the sudden cardiac arrest event. Before they arrive, emergency responders are informed of event details including shocks given and patient ECG to continue with appropriate lifesaving actions.
- Featuring an IP55 rating against dust and water, the LIFEPAK CR2 works in challenging conditions.
Waveform |
Biphasic Truncated Exponential with voltage and duration compensation for patient impedance. |
Patient impedance range |
10 - 300 ohms |
Energy accuracy |
10% of the energy setting into 50 ohms |
Output energy sequence |
Multiple levels, configurable from 150 joules to 360 joules |
Energy default |
200J, 300J, 360J (adult) |
Shock Advisory SystemTM |
An ECG analysis system that advises whether a shock is appropriate. |
cprINSIGHTTM analysis technology |
Enables the defibrillator to analyze the patient's heart rhythm while CPR is being performed |
CPR coaching |
Instructions for adult and pediatric CPR, including feedback when no CPR is detected, rate and depth guidance, a metronome and instructions on hand placement. |
Time to shock at 360J after CPR (with cprINSIGHT enabled) |
- Semi-automatic: < 7 seconds |
Charge time |
0 seconds for first 150J or 200J shock (as device is pre-charged). With cprINSIGHT enabled, subsequent shocks will be charged during CPR and ready to shock at the end of the CPR period. |
User interface |
The user interface includes voice prompts and audible tones |
ClearVoiceTM technology |
Detects background noise and adjusts audio and voice prompts to ensure they can be heard clearly in noisy environments. |
Battery |
- Type:Lithiummanganesedioxide(Li/MnO2),12.0V,4.7amp- hours. |
Electrode pads |
- Pads: Can be used on both adult and pediatric patients. |
Data storage |
- Memory type: Internal digital memory (flash RAM). |
Communications |
USB, Wireless 802.11 b/g/n data transfer to LIFELINKcentralTM AED program manager or LIFENET® System. |